Processing, Please wait...

  • Home
  • About Us
  • Search:
  • Advanced Search

Growing Science » Current Chemistry Letters » Determination and validation of tiaprofenic acid in human plasma: A detailed LC-MS/MS-based analysis following ICH M10 guidelines and the accuracy profile approach

Journals

  • IJIEC (777)
  • MSL (2643)
  • DSL (690)
  • CCL (528)
  • USCM (1092)
  • ESM (421)
  • AC (562)
  • JPM (293)
  • IJDS (952)
  • JFS (101)
  • HE (32)
  • SCI (26)

CCL Volumes

    • Volume 1 (23)
      • Issue 1 (7)
      • Issue 2 (5)
      • Issue 3 (6)
      • Issue 4 (5)
    • Volume 2 (26)
      • Issue 1 (7)
      • Issue 2 (6)
      • Issue 3 (6)
      • Issue 4 (7)
    • Volume 3 (30)
      • Issue 1 (7)
      • Issue 2 (10)
      • Issue 3 (8)
      • Issue 4 (5)
    • Volume 4 (21)
      • Issue 1 (5)
      • Issue 2 (5)
      • Issue 3 (6)
      • Issue 4 (5)
    • Volume 5 (20)
      • Issue 1 (5)
      • Issue 2 (5)
      • Issue 3 (5)
      • Issue 4 (5)
    • Volume 6 (20)
      • Issue 1 (5)
      • Issue 2 (5)
      • Issue 3 (5)
      • Issue 4 (5)
    • Volume 7 (15)
      • Issue 1 (4)
      • Issue 2 (4)
      • Issue 3 (4)
      • Issue 4 (3)
    • Volume 8 (20)
      • Issue 1 (5)
      • Issue 2 (5)
      • Issue 3 (5)
      • Issue 4 (5)
    • Volume 9 (20)
      • Issue 1 (5)
      • Issue 2 (5)
      • Issue 3 (5)
      • Issue 4 (5)
    • Volume 10 (43)
      • Issue 1 (5)
      • Issue 2 (7)
      • Issue 3 (17)
      • Issue 4 (14)
    • Volume 11 (43)
      • Issue 1 (14)
      • Issue 2 (11)
      • Issue 3 (10)
      • Issue 4 (8)
    • Volume 12 (78)
      • Issue 1 (21)
      • Issue 2 (22)
      • Issue 3 (20)
      • Issue 4 (15)
    • Volume 13 (68)
      • Issue 1 (23)
      • Issue 2 (17)
      • Issue 3 (16)
      • Issue 4 (12)
    • Volume 14 (68)
      • Issue 1 (20)
      • Issue 2 (13)
      • Issue 3 (22)
      • Issue 4 (13)
    • Volume 15 (33)
      • Issue 1 (13)
      • Issue 2 (20)

Keywords

Supply chain management(168)
Jordan(165)
Vietnam(151)
Customer satisfaction(120)
Performance(115)
Supply chain(112)
Service quality(98)
Competitive advantage(97)
Tehran Stock Exchange(94)
SMEs(89)
optimization(87)
Sustainability(86)
Artificial intelligence(85)
Financial performance(84)
Trust(83)
TOPSIS(83)
Job satisfaction(81)
Genetic Algorithm(78)
Factor analysis(78)
Social media(78)


» Show all keywords

Authors

Naser Azad(82)
Zeplin Jiwa Husada Tarigan(66)
Mohammad Reza Iravani(64)
Endri Endri(45)
Muhammad Alshurideh(42)
Hotlan Siagian(40)
Dmaithan Almajali(37)
Jumadil Saputra(36)
Muhammad Turki Alshurideh(35)
Ahmad Makui(33)
Barween Al Kurdi(32)
Hassan Ghodrati(31)
Basrowi Basrowi(31)
Sautma Ronni Basana(31)
Mohammad Khodaei Valahzaghard(30)
Shankar Chakraborty(29)
Ni Nyoman Kerti Yasa(29)
Haitham M. Alzoubi(28)
Sulieman Ibraheem Shelash Al-Hawary(28)
Prasadja Ricardianto(28)


» Show all authors

Countries

Iran(2192)
Indonesia(1311)
Jordan(813)
India(793)
Vietnam(510)
Saudi Arabia(478)
Malaysia(444)
China(231)
United Arab Emirates(226)
Thailand(160)
United States(114)
Ukraine(110)
Turkey(110)
Egypt(106)
Peru(94)
Canada(93)
Morocco(86)
Pakistan(85)
United Kingdom(80)
Nigeria(78)


» Show all countries

Current Chemistry Letters

ISSN 1927-730x (Online) - ISSN 1927-7296 (Print)
Quarterly Publication
Volume 13 Issue 4 pp. 707-716 , 2024

Determination and validation of tiaprofenic acid in human plasma: A detailed LC-MS/MS-based analysis following ICH M10 guidelines and the accuracy profile approach Pages 707-716 Right click to download the paper Download PDF

Authors: Houda Bouchafra, Aimen El Orche, Choukri El Khabbaz, Amine Cheikh, Miloud El Karbane, My El Abbes Faouzi, Yahia Cherrah, Lhoussaine Zarayby, Aziz Hirri

DOI: 10.5267/j.ccl.2024.4.003

Keywords:

Abstract: The validation of bioanalytical methods holds critical importance for regulatory agencies and organizations dedicated to ensuring the safety, efficacy, and quality of pharmaceuticals. In this context, the recent release of the ICH M10 guideline in May 2022 represents a significant milestone in standardizing bioanalytical method validation globally. However, this guideline lacks explicit experimental protocols for implementation. In this study, we address the practical implementation of the newly released ICH M10 guideline by providing a detailed validation protocol for a bioanalytical method. Our method specifically targets tiaprofenic acid, a widely used nonsteroidal anti-inflammatory drug. Tiaprofenic acid is a critical component in bioequivalence studies, underscoring the necessity for precise and accurate quantification within complex biological matrices. The integration of the accuracy profile approach, a statistical tool, enhances the significance of this work. This approach aids in assessing the accuracy and precision of bioanalytical methods, establishing confidence intervals around measured concentrations, and quantifying the level of accuracy and precision expected when using the validated method.

How to cite this paper
Bouchafra, H., Orche, A., Khabbaz, C., Cheikh, A., Karbane, M., Faouzi, M., Cherrah, Y., Zarayby, L & Hirri, A. (2024). Determination and validation of tiaprofenic acid in human plasma: A detailed LC-MS/MS-based analysis following ICH M10 guidelines and the accuracy profile approach.Current Chemistry Letters, 13(4), 707-716.

Refrences
1. Pandey S., Pandey P., Tiwari G., & Tiwari R. (2010) Bioanalysis in drug discovery and development. Pharm. Methods., 1 (1) 14‑24.
2. Swann P. G., & Shapiro M. A. (2011) Regulatory considerations for development of bioanalytical assays for biotechnology products. Bioanalysis., 3(6) 597‑603.
3. EMA. European Medicines Agency. (2019). ICH M10 on bioanalytical method validation - Scientific guideline. https://www.ema.europa.eu/en/ich-m10-bioanalytical-method-validation-scientific-guideline
4. Plosker G. L., & Wagstaff A. J. (1995) Tiaprofenic Acid. Drugs., 50 (6) 1050‑75.
5. Chow S. C. (2014) Bioavailability and Bioequivalence in Drug Development. Wiley Interdiscip Rev Comput Stat., 6 (4) 304‑12.
6. Tiwari G., & Tiwari R. (2010) Bioanalytical method validation: An updated review. Pharm Methods., 1 (1) 25‑38.
7. Deshpande M. M., Kasture V. S., & Chavan M. M., (2019) Bioanalytical Method Development and Validation: A Review. In: Recent Advances in Analytical Chemistry https://www.intechopen.com/chapters/66021
8. Ward G. T., Stead J. A., & Freeman M. (1982) A Rapid and Specific Method for the Determination of Tiaprofenic Acid in Human Plasma by High-Performance Liquid Chromatography. J Liq Chromatogr. 5 (1) 165‑74.
9. Sultana N., Arayne M. S., & Shahzad W. (2010) Simultaneous Determination of Ceftriaxone Sodium and Non Steroidal Anti‐Inflammatory Drugs in Pharmaceutical Formulations and Human Serum by RP‐HPLC. J Chin Chem Soc., 57 (6) 1278‑85.
10. Sochor J., Klimeš J., Sedláček J., Somolíková B., & Slovenčík D. (2000) HPLC analysis of tiaprofenic acid in the samples of whole blood using L-L and S-L extractions. J Liq Chromatogr Relat Technol., 23(20) 3191‑201.
11. Nawaz M. (2012) Simultaneous determination of non-steroidal anti-inflammatory drugs in pharmaceutical formulations and human serum by reversed phase high performance liquid chromatography. Quím Nova., 35 939‑43.
12. Geisslinger G., Menzel S., & Brune K. (1996) Stereospecific determination of tiaprofenic acid in plasma: problems with drug degradation. J Chromatogr B Biomed Sci App., 675 (1) 77‑81.
13. Lee, X. P., Kumazawa, T., Hasegawa, C., Arinobu, T., Kato, A., Seno, H., & Sato, K. (2010). Determination of nonsteroidal anti-inflammatory drugs in human plasma by LC-MS-MS with a hydrophilic polymer column. Forensic Toxicol., 28 (2) 96‑104.
14. Nemoto T., Lee X. P., Kumazawa T., Hasegawa C., Fujishiro M., Marumo A., et al. (2014) High-throughput determination of nonsteroidal anti-inflammatory drugs in human plasma by HILIC-MS/MS. J Pharm Biomed Anal., 88 71‑80.
15. Marlet C., & Lognay G. (2010) Development and validation by accuracy profile of a method for the analysis of monoterpenes in indoor air by active sampling and thermal desorption-gas chromatography-mass spectrometry. Talanta., 82 (4) 1230‑9.
16. El Khabbaz, C., El Orche, A., Bouatia, M., Cheikhǁ, A., Faouzi, M. E. A., Cherrahǁ, Y., ... & Bouchafra, H. (2022). Development and Validation of a Bioanalytical Method for the Quantification of Clopidogrel in Human Plasma by LC-MS/MS using the Accuracy Profiles. extraction (SPE), 12, 16.
17. De Saint Jores C., Klein R., Legendre A., Dugay J., Thiébaut D., & Vial J. (2022) Preparation of Thermodesorption Tube Standards: Comparison of Usual Methods Using Accuracy Profile Evaluation. Separations. 9(8) 226.
18. Ouakhssase, A., Fatini, N., & Ait Addi, E. (2021). Chemometric Approach Based on Accuracy Profile and Data Chronological Distribution as a Tool to Detect Performance Degradation and Improve the Analytical Quality Control for Aflatoxins’ Analysis in Almonds Using UPLC–MS/MS. ACS omega, 6(19), 12746-12754.
19. Hubert, P., Nguyen-Huu, J. J., Boulanger, B., Chapuzet, E., Chiap, P., Cohen, N., ... & Valat, L. (2004). Harmonization of strategies for the validation of quantitative analytical procedures: a SFSTP proposal—part I. J Pharm Biomed Anal., 36 (3) 579‑86.
20. Feinberg M. (2007) Validation of analytical methods based on accuracy profiles. J Chromatogr A. 1158 (1) 174‑83.
  • 17
  • 1
  • 2
  • 3
  • 4
  • 5

Journal: Current Chemistry Letters | Year: 2024 | Volume: 13 | Issue: 4 | Views: 806 | Reviews: 0

Related Articles:
  • Development and validation of a green RP-HPLC method for detection and quan ...
  • Quantification of Alectinib in spiked rabbit plasma using liquid chromatogr ...
  • Three spectrophotometric approaches for measuring ratio spectra of Ivabradi ...
  • Isocratic RP-UHPLC method development and validation of stability-indicatin ...
  • Novel membrane sensor for determination of lamotrigine in pharmaceuticals a ...

Add Reviews

Name:*
E-Mail:
Review:
Bold Italic Underline Strike | Align left Center Align right | Insert smilies Insert link URLInsert protected URL Select color | Add Hidden Text Insert Quote Convert selected text from selection to Cyrillic (Russian) alphabet Insert spoiler
winkwinkedsmileam
belayfeelfellowlaughing
lollovenorecourse
requestsadtonguewassat
cryingwhatbullyangry
Security Code: *
Include security image CAPCHA.
Refresh Code

® 2010-2026 GrowingScience.Com